TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
75 / 81
COMMUNICATOR
User calls doesn not work.
After entering the Installation Program, enter the phone
numbers at 06 01 ~ 06.
Make sure option 2 is selected at address 50 01. When you
set 3 at address 50 02, the number of attempts will be set
to 3.
Reports cannot send Central
Monitoring Station.
After entering the Installation Program, enter the account
number at 04 01 for first CMS
Set CMS numbers at 05 01 and 05 03 for CMS 2
Make sure option 1 is selected at address 50 01.
I cant remotely arm the control
panel by phone.
After entering the Installation Program, enable option 1 at
15 01. Set the ring count at 15 02.
When you call the control panel by phone after
confirmation sound dial *code# and after confirmation
dial *1# to arm system.
Control Panel does not send SMS
Make sure option 3 is turned on at address 50 01.
In case of alarm all registered
phones are dialed or the panel
calls the same number more than
once.
Edit the options End Calls on Firs Confirmation and End
Calls By Pressing any Key under the Communicator Menu
as your needs.
Alarm panel continuously calls by
phone.
Control panel calls the users as many time as you set
after alarm condition. After you answer your phone, press
* to stop calls. Alarmı çözmek ve sireni susturmak için ise
ek olarak *şifre# onay sesinden sonra *0# yapınız.
Can I turn off all SMS?
Yes, Communicator - General Settings Turn off 3, you
will close all SMS.
Can I use a mobile application
when there is no internet package
on my SIM card?
If your SIM card does not have internet access, you cannot
use the mobile application. GSM; Allows calls and SMS
sending. GPRS; Provides an Internet (data) connection.
Sim card is connected but control
panel cant make calls or send
messages to CMS.
Probably the SIM card pin code is not turned off. You
cannot operate until the pin code is removed.
Phone Calls and SMS are working
but I have a problem with Mobile
application not stable.
Check the GSM / GPRS signal level. This problem may
occur when the signal level is low. A better quality signal
is required for the GPRS connection
I cannot make CMS
communication with the
GSM/GPRS module.
i. The SIM card used may not have internet on by the
network service provider.
ii. GPRS communication may be turned off in the module
settings section (factory setting is on).
iii. Your CMS account number, port number, or IP address
may be incorrect.
iv. There may not be Teknim Receiver software in CMS
attempting to establish a connection.