TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
76 / 81
COMMU
NICATOR
I cannot send SMS.
i. The SMS sending setting may be off. In the factory
settings, SMS sending is off and needs to be turned on
after entering the phone number.
ii. At the beginning of the number you want to send an
SMS "COUNTRY CODE 00" (for example, Turkey 0090)
must be entered. Some mobile operators cannot send
SMS without country code at the beginning.
Some events do not send SMS, do
not send message to CMS or make
calls.
Under the report masks menu, settings such as call, sms
or CMS notification can be selected and customized. Some
options are closes as a factory default.
When I call the panel by phone,
the panel does not respond.
At the ”Remote Access Settings make sure option 1 is
turned on.
BATTERY
Control Panel does not operate
from battery only.
If the control panel will be operated only by battery
without mains connection, after the battery connection is
made, press and hold the Start button on the panel board
for 3 seconds. Otherwise, the battery will not turn on until
power is applied.
Battery charge light does not turn
off when power is göne.
The battery charge light will go out in 1 minute, if the
power goes out during the charging phase, it can detect in
1 minute.
How do we know that the panel
works?
If the status led on the panel flashes every 3 seconds, the
panel is running. Flashes at different times during arming
and disarming.
The charging light is on
continuously.
To maximize the life of your battery, a charged battery
operates in 56sec charge, 4sec discharge mode.
SOFTWARE
Which Code should I use to login
from PC Configuration Software?
If you are going to program Pars alarm systems via a PC,
you should get the PC configuration program first. When
connecting to the control panel with this software, you
can log in using the Installation Code of the panel. Factory
Default: 9999
When making a PC connection, I
get a disconnected error.
When connecting the PC to the panel, make sure that the
alarm is not armed.
How to change user codes with
configuration software?
For security reasons, the codes cannot be changed from
the configuration software.
CODES
While everything appears normal
on the panel, I get "Access Denied"
error when try to login to Installer
Program.
Make sure your code is correct. If your code is correct, you
may not be able to log in due to a previously occurring
alarm condition (Panic Alarm, Medical Alarm etc.). You
cannot log in unless the alarm restores.
I receive an “ERROR: WRONG
PASSWORD” warning when I try to
arm the system.
1: Make sure your code is entered correctly.
2: Make sure that the Fx key is not active, if the Fx key is
active, the ready light flashes.
How to delete user Codes?
User codes can be deleted by entering 0000 in the section
of user codes.
When the user code is deleted,
will the remote keyfob which
connected to the user code work?
When the user code is deleted, the remote control keyfob
is also automatically deleted.