TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
77 / 81
CODES
I forgot my master code, what
should I do??
Contact technical service.
Smoke detector is not reset by
user code after gives alarm,
although it is supplied from the
PGM output. Red light stays on, it
resets when I unplugged the
detector from base.
Make sure the smoke detector is connected correctly and
make sure that its parameters are correctly entered.
How many external sirens can be
connected to the alarm panel?
When using Teknim brand external siren, 2 sirens can be
connected. The second siren must have the internal siren
jumper connected.
Can I connect two different unit to
the same PGM?
No, there may not be a correct connection because the
parameters are different.
How many units can I connect to
the same PGM in one type?
For max limit, connection must be made by calculating the
max current to be drawn by the devices. For example, the
TSD-5135 smoke detector consumes 10 mA, therefore
Max. 10 pcs smoke detector can be connected.
How many detector can I connect
to control panel?
There is no max limit, the total current of the panel must
be calculated and the connection must be made
accordingly.
Can I define a remote keyfob
controller to two different
users??
No, you cant define same keyfob to another user it gives
!! Available Warning.
DİĞER
How many remote keyfob can I
use in the system?
Maximum 11 keyfob can be used with user codes.
Fire detector is constantly gives
Alarm.
1: Be sure to make the appropriate connection by referring
to the user manual.
2: Make sure that the type of zone connected to the fire
detector is selected as Fire.
3: Make sure PGM usage type is selected as Fire
detector“.
4: Make sure that the PGM parameter is entered for the
minimum reset time in seconds of the connected detector.
The system gives alarm when I
walk around in the house even
though I'm arming the system as
Stay Mode.
You have to define Include Home Arming to related zone.
Panel functions do not work
properly after firmware upgrade.
After firmware upgrade, the control panel settings return
to the factory defaults.