TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
7.5.3 Zon Type
The zone type can be selected according to the type of zone and the location which detector
installed. The information which will be send to CMS will be defined in this section according to zone
type. Only one of these types can be selected for a zone.
Zone types are listed in the table below.
This option is available for zones to which door-mounted magnetic
contacts are connected.
This option is available for zones with window-mounted magnetic
contacts.
This option is available for zones with indoor sensors.
This option is available for zones with outdoor sensors.
This type of selected zones are continuously active whether the system is
armed or not. Sends 24 Hour alarm information to CMS.
This type of selected zones are continuously active whether the system is
armed or not. Sends Fire Alarm information to CMS. Can be used the zones
which connected fire detector. Fire alarm can be silenced by entering code
on keypad.
This type of selected zones are continuously active whether the system is
armed or not. Sends Panic alarm information to CMS. Can be use for Panic
buttons. Siren will not gives warning for this zone type.
This type of selected zones are continuously active whether the system is
armed or not. Sends Duress information to CMS. Siren will not gives
warning for this zone type.
This type of selected zones are continuously active whether the system is
armed or not. Sends Tamper information to CMS. This zone type can be
used for tamper connections of the PIR, siren, panel etc.
This type of selected zones are continuously active whether the system is
armed or not. Sends Medical Alarm information to CMS. This zone type can
be selected when an emergency button is install to the system for the
person who need for care.
This type of selected zones are continuously active whether the system is
armed or not. Sends any information to CMS which user selected.
System will be Armed if this zone goes NC and Disarmed if goes NO.