TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
29 / 81
Auto Arm Days
You can set which days will be arm automatically.
LED Keypad;
[12] [02] [1234567] [√ OK]
LCD Keypad;
[Panel Settings OK][ Auto Arm/Disarm OK][ Auto Arm Days 1234567][OK]
PS: Days of the week are; 1: Sunday 2: Monday 3: Tuesday 4: Wednesday 5: Thursday 6: Friday
7: Saturday.
Auto Arm Time
You can set which time will be arm automatically.
LED Keypad;
[12] [03] [SS:DD] [√ OK]
LCD Keypad;
[Panel Settings OK][ Auto Arm/Disarm OK][ Auto Arm Time SS:DD] [√ OK]
Auto Disarm Partitions
You can set which partitions will be Disarm automatically.
LED Keypad;
[12] [04] [1-2-3-4] [√ OK]
LCD Keypad;
[Panel Settings OK][Auto Arm/Disarm OK][Auto Disarm Partitions A-B-C-D][√ OK]
Auto Disarm Days
You can set which days will be disarm automatically.
LED Keypad;
[12] [05] [1234567] [OK]
LCD Keypad;
[Panel Settings OK][ Auto Arm/Disarm OK][ Auto Disarm Days 1234567][OK]
PS: Days of the week are; 1: Sunday 2: Monday 3: Tuesday 4: Wednesday 5: Thursday 6: Friday
7: Saturday.
Auto Disarm Time
You can set which time will be disarm automatically.
LED Keypad;
[12] [06] [SS:DD] [√ OK]
LCD Keypad;
[Panel Settings OK][ Auto Arm/Disarm OK][ Auto Disarm Time SS:DD] [√ OK]
Inactivity Arm Partitions
You can set which partitions will be arm when there is no movement in it.
LED Keypad;
[12] [07] [1-2-3-4] [OK]
LCD Keypad;
[Panel Settings OK][ Auto Arm/Disarm OK][Inactivity Arm Partitions A-B-C-D][ OK]