TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
Exit Delay Extension: When this option is active; if any zone which programmed as input-output is
still active during exit delay, exit delay duration will automatically continue until the zone closed.
Double Hit: When this option is active, system gives alarm when the same zone gives 2x activation
during the cross zone time period which defined before. Double Hit function is only valid for the
zones which selected as cross zones.
• LED Keypad; [10] [01] → [2-3-4-5-6] → [√ OK]
• LCD Keypad; [Panel Settings √ OK] → [General Settings √ OK] → [Panel Options 2-3-4-5-6] → [√ OK]
Output Polarization
PGM and SRN gives -12V. This option selecets if this outputs gives -12V when its activated or
passive.
• LED Keypad; [10] [02] → [1-4] → [√ OK]
• LCD Keypad; [Panel Settings √ OK] → [General Settings √ OK] → [Output Polar. 1-4] → [√ OK]
Default Settings Requests
You can choose the reset types in this section.
• LED Keypad; [10] [03] → [1-2] → [√ OK]
• LCD Keypad; [Panel Settings √ OK] → [General Settings √ OK] → [Default Set. Req. 1-2] → [√ OK]
PS: You can only chose reset types in Installer Menu.
Reset Permission
You can give reset permission for each reset type.
Reset Panel Settings Permission
• LED Keypad; [10] [04] → [1-2] → [√ OK]
• LCD Keypad; [Panel Settings √ OK] → [General Settings √ OK] → [Reset Permission 1-2] → [√ OK]