TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
47 / 81
LED Keypad;
[50] [04] → [XX] → [√ OK]
• LCD Keypad;
[Communicator √ OK]→[General Settings √ OK]→[Test Interval XX]→[√ OK]
First Test Time
The first test time to be sent to the CMS is entered in this section.
• LED Keypad;
[50] [05] → [HH:MM] → [√ OK]
• LCD Keypad;
[Communicator √ OK]→[General Settings √ OK]→[First Test At HH:MM]→[√ OK]
Call Delay
This section specifies how many seconds to delay during between two-number dialing. Value can be
entered 1-30sec.
• LED Keypad;
[50] [06] → [XX] → [√ OK]
• LCD Keypad;
[Communicator √ OK]→[General Settings √ OK]→[Call Delay XX]→[√ OK]
CMS 1 Format
CMS format can be selected as Contact ID or SIA.
0: Contact ID – 1: SIA
• LED Keypad;
[50] [07] → [0-1] → [√ OK]
• LCD Keypad;
[Communicator √ OK]→[General Settings √ OK]→[CMS 1 Format]→[√ OK]
CMS 2 Format
CMS format can be selected as Contact ID or SIA.
0: Contact ID – 1: SIA
• LED Keypad;
[50] [08] → [0-1] → [√ OK]
• LCD Keypad;
[Communicator √ OK]→[General Settings √ OK]→[CMS 2 Format]→[√ OK]
Partition A CMS
Which CMS to send the reports for Partition A is selected in this section.
1: CMS 1 – 2: CMS 2
• LED Keypad;
[50] [09] → [1-2] → [√ OK]
• LCD Keypad;
[Communicator √ OK]→[General Settings √ OK]→[Partition A CMS 1-2]→[√ OK]