TD-1/07-008
30 / 83
1.option = CMS
2.option = User Phone
3.option.= CMS Restore
4.option = User Phone
Restore
5.option = Record
Memory
Address
51 25
51 26
51 27
51 28
51 29
51 30
51 31
51 32
Value
-
-
-
-
-
1, 2, 5
-
5
Event Codes
(Contact ID)
Address
52 25
52 26
52 27
52 28
52 29
52 30
52 31
52 32
Value
-
-
-
-
-
0000
-
0000
USER PHONE DIALER
Phone Memory
1
2
3
4
5
6
Phone
Number
Address
06 01
06 02
06 03
06 04
06 05
06 06
Value
---
---
---
---
---
---
Telephone Settings
User Phone Dialer
Active/Not Active
Cancel Calls on
Disarm
Alarm on Line
Fail
Confirm by Single
Button
Dial Attempt
Settings
Address
2.option(50 01)
4.option(50 01)
5.option(50 01)
6.option(50 01)
50 02
Value
OFF
ON
OFF
OFF
3 times
Redialing Pause
Cancel Calls on
Confirm
Make Siren
Silence on
Confirm
AC Fail Call Delay
-
Settings
Address
50 09
50 01 de 7.seçenek
50 01 de
8.seçenek
10 08
Value
3 seconds
OFF
OFF
0 minute
Message Settings
Out of Partition
A Partition
B Partition
C Partition
D Partition
Numbers that
will be called
Address
50 16
50 17
50 18
50 19
50 20
Value
All phone numbers
All phone numbers
All phone
numbers
All phone numbers
All phone numbers
CENTRAL MONITORING STATION SETTINGS
Numbers
1.Account No
2.Account No
Central M.
Station-1
(CMS-1)
Tel No
Central M.
Station-2
(CMS-2)
Tel No
Central M.
Station-1
Second
Tel No
Central M.
Station-2
Second
Tel No
Address
04 01
04 02
05 01
05 02
05 03
05 04
Value
0000
0000
---
---
---
---
Settings
CMS Calling
Enable/Disable
Cancel Calls on Disarm
Alarm on Line Fail
Dial
Attempt
Answer Wait
Time
Address
1. option (50 01)
4.option (50 01)
5.option (50 01)
50 02
50 03
Value
OFF
ON
OFF
3 times
30 seconds
Periodic Report
Interval
First Periodic Test Time
AC Fail Call Delay
-
-
Address
50 04
50 05
10 08
Value
24 (hour)
00:00
15 minute

Table of Contents