Note1. Indication of the days is 1.Monday, 2.Tuesday, 3.Wednesday, 4.Thursday, 5.Friday, 6.Saturday, 7.Sunday
Note2. “Disable” sometimes means ‘closed’ or ‘NO’ ; “Enable” sometimes means ‘open’ or ‘NC’.
Note3. Keypad settings are stored in Keypad not in Panel.
Note4. 4+2 codes are not defaulted. If 4+2 will be used, necessary codes should be entered manually.
6. LOADING FACTORY DEFAULTS
Panel has two types of returning factory defaults.
o Loading default Codes ( from Installer or Master Program)
o Loading default Panel Settings ( only from Installer Program)
Firstly, ensure that reset permissions are enabled and select reset type then activate reset.
Do jumper setting as following table to restore Panel Settings factory defaults. You don’t need change
jumper setting to restore codes to factory defaults.
RESTORING CODES TO FACTORY DEFAULTS
Firstly, ensure that reset code permission is enabled installer program(It is selected as a default). Make
following steps to reset codes.
4 (long) 9 9 9 9 (Enter Installer Program. Default installer code is 9 9 9 9 ).
LED Keypad
10 06 1(ON) √ ( This step isn’t needed to be done if default setting isn’t changed)
10 04 1(ON) √