o Backlight zones
Backlight is seen when selected zone is opened.
1. option=1. Zone, 2. Option=2. Zone, 3. Option=3. Zone, 4. Option=4. Zone
5. option=5. Zone, 6. Option=6. Zone, 7. Option=7. Zone, 8. Option=8. Zone
Address = 99 03 < IP, MP >
To see value : LED 99 03 (wait)
To change value : LED 99 03 S ........S √
S = Multiple choice selection
Default Value : 1 = 1.zone
Example : To activate backlight of zone 1 and zone 2 do
99 03 1(ON) 2(ON)
o Emergency Buttons
Panic, Fire, Duress buttons can be closed to usage. Meanings of options are in the following.
1. option = Panic (Panic), 2. option=Fire, 3. option= Duress, 4.option= Keypad Tamper
Address = 99 04 < IP, MP >
To see value : LED 99 04 (wait)
To change value : LED 99 04 S ........S √
S= Multiple choice selection
Default Value : 1= ON , 2= ON, 3= ON , 4= ON
Example : To disable Fire button of Keypad do
99 03 2(OFF)
o Warning Beeps
Keypad warning beeps can be closed in this address. Meaning of options is in the following.
1. option = Exit Delay beep, 2. option = Arm beep , 3.option = Alarm beep,
4. option = Trouble beep, 5. option = Button click beep, 6.option = Confirmation beep
Address = 99 05 < IP, MP >
To see value : LED 99 05 (wait)
To change value : LED 99 05 S ........S √
S = Multiple choice selection
Default Value : All beeps are active
Example : To silent Trouble Beep do
99 05 4 (OFF)
o Trouble Beeps
Trouble beeps can be closed in this address. Meaning of options is in the following.
1. option= AC fail, 2. option = Low Battery ,3. option=Time-date loss,
4.option = Telephone Line fail 5. option = Zone trouble 6.option = Battery loss
Address= 99 06 < IP, MP >
To see value : LED 99 06 (wait)
To change value : LED 99 06 S........S √
S = Multiple choice selection
Default value : All beeps are active
Example : To silent telephone line fail do
99 06 4(OFF)
8.8.2. VPC301 LCD Keypad Inner Settings
o Open Chime
Chime activates when selected zone is opened.
< IP, MP >
To see value :
LCD 3-KEYPAD SETTING → CUSTOMISE→ CHIME ON 1-8 (wait)
ZONES:
To change value :