EasyManua.ls Logo

Teknim VAP404 - Event Logs

Teknim VAP404
83 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TD-1/07-008
65 / 83
Events that is not belongs to any Partition
Address = 50 11 < IP >
To see value :
LED 50 11 (wait)
LCD 5-COMMUNICATOR→ GENERAL SETTINGS → COMMON CMS(wait)
To change value :
LED 50 11 S S √
LCD 5-COMMUNICATOR → GENERAL SETTINGS → COMMON CMS
S S √
S S = Multi-choice selection 1, 2
Default Value : 1 =ON
Example : To send messages CMS-1 and CMS-2 do “ 50 11 1(ON) 2(ON) √ “
Events that is belongs to A D Partition
Address : 50 12-15 < IP >
Default Value : 1 (ON) (CMS-1)
o User Phone Selection that Messages will be Sent to
This setting defines which events will be sent to which Phone number. Arm/Disarm, alarms, bypass events,
zon troubles are called related to their partitions.
Note: Keypad alarms(Panic, Fire, Duress, Tamper) aren’t belong to any partition.
Meanings of options as following;
1. option
Tel-1
2. option
Tel-2
3. option
Tel-3
4. option
Tel-4
5. option
Tel-5
6. option
Tel-6
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
Events that is not belong to any Partition
Address : 50 16 < IP >
To see value :
LED 50 16 (wait)
LCD 5-COMMUNICATOR→ GENERAL SETTINGS → PARTITION A CMS (wait)
To change Value :
LED 50 16 S S S S S S √
LCD 5-COMMUNICATOR → GENERAL SETTINGS → PARTITION A CMS
S S S S S S √
S S S S S S : Multi-choice selection, (1, 2, 3, 4, 5, 6)
Default Value : All selection is ON
Example : To select all phones do
“ 50 16 1(ON) 2(ON) 3(ON) 4(ON) 5(ON) 6(ON) √ “
Events belong to A D Partition
Address = 50 17-20 < IP >
Default Value : All options are ON
8.6.2. Event Logs
Installer decides which event will be informed to Central M. Station1-2 and/or user1 to 5 and/or Memory.
Events are separated into 3 groups. These are Alarms, Troubles, and Events. Meaning of options is in the
following table.

Table of Contents