To see value :
LED 50 08 (wait)
LCD 5-COMMUNICATOR→ GENERAL SETTINGS → CMS 2 FORMAT (wait)
To change value :
LED 50 08 F √
LCD 5-COMMUNICATOR→ GENERAL SETTINGS → CMS 1 FORMAT
[FORMAT] √
(Select using B(left) and C(right) buttons)
F = CMS format type, 0 ~ 1
Default Value : 0, Contact ID
To set CMS-2 contact as Contact ID do 50 08 0 √
o DTMF 4+2, 4+1, 3+2, 3+1 Format Settings
Defines details of communication format of Central Monitoring Station if “1” is entered in 50 07-08.
CMS-1
Address= 50 09 < IP >
To see value :
LED 50 09 (wait)
LCD 5-COMMUNICATOR→GENERAL SETTINGS → 09- CMS 1 SETTINGS (wait)
To change value :
LED 50 09 F F F √
LCD 5-COMMUNICATOR → GENERAL SETTINGS → 09- CMS 1 SETTINGS
F F F √
FFF = Multiple choice selection (1,2,3)
Default Value : 1=OFF, 2=OFF, 3=OFF
Example : To set format as 4+1 do
“ 50 09 1(OFF) 2(ON) √ “
CMS-2
Address= 50 10 < IP >
To see value :
LED 50 10 (wait)
LCD 5-COMMUNICATOR→ GENERAL SETTINGS → 10- CMS 2 SETTINGS (wait)
To change value :
LED 50 10 F F F √
LCD 5-COMMUNICATOR → GENERAL SETTINGS → 10-CMS 2 SETTINGS
F F F √
F F F = Multiple choice selection (1,2,3)
Default Value : 1=OFF, 2=OFF, 3=OFF
Example : To set format as 3+2 do
50 10 1(ON) 2(OFF) √
o CMS Selection that Messages will be Sent
This setting defines which events will be sent to which CMS. Arm/Disarm, alarms, bypass events, zon
troubles are called related to their partitions.
Note: Keypad alarms(Panic, Fire, Duress, Tamper) aren’t belong to any partition.
Meanings of Options in this address are in the following;
1.option = CMS-1 2.option = CMS-2