Example : To set Periodic Test Report Interval to 24 hours do 50 04 24 √
o Central Monitorin Station(CMS) Periodic Report Time
Address = 50 05 < IP >
To see value :
LED 50 05 (wait)
LCD 5-COMMUNICATOR → GENERAL SETTINGS → FIRST TEST AT (wait)
To change value :
LED 50 05 R R √
LCD 5-COMMUNICATOR → GENERAL SETTINGS → FIRST TEST AT
TT TT HOUR(S) √
TT TT= Periodic test first time
Default Value : 00:00
Example : To set Periodic Test First Time to 16:00 do 50 05 1600 √
o Redialing Pause
Address = 50 06 < IP >
To see value :
LED 50 06 (wait)
LCD 5-COMMUNICATOR → GENERAL SETTINGS → REDIALING PAUSE(wait)
To change value :
LED 50 06 R R √
LCD 5-COMMUNICATOR → GENERAL SETTINGS → REDIALING PAUSE
TT SECOND(S) √
TT = Redialing Pause Interval
Default Value : 30 sec.
Example : To set Redialing Pause Interval to 30 sec. do 50 06 30 √
o Central Monitoring Station-1(CMS-1) Format
CMS-1 communication format is configured here. Meaning of data entered this address is in the following;
0 = Contact ID 1 = DTMF 4+2,4+1, 3+2, 3+1 50 07 address includes detailed settings)
Address: 50 07 < IP >
To see value :
LED 50 07 (wait)
LCD 5-COMMUNICATOR → GENERAL SETTINGS → CMS 1 FORMAT (wait)
To change value :
LED 50 07 F √
LCD 5-COMMUNICATOR → GENERAL SETTINGS→ CMS 1 FORMAT
[FORMAT] √
(Select using B(left) and C(right) buttons)
F = CMS format type, 0 ~ 1
Default Value : 0, Contact ID
Example: : To set CMS-1 contact as Contact ID do 50 07 0 √
o Central Monitoring Station-2(CMS-2) Format
CMS-1 communication format is configured here. Meaning of data entered this address is in the following;
0 = Contact ID 1 = DTMF 4+2,4+1, 3+2, 3+1 (50 08 address includes detailed settings)
Address = 50 08 F< IP >