Functions of Partition buttons change if SPT(Smart Partition Technology) is enabled. A(HOME) button
arms zones except interior zones. B(Window) button arms window zones. C(Door) button arms Door zones.
D(AWAY) button arms all zones.
Quick Arm enables arming without user code(User press partition button long that he/she wants to arm).
If Automatic siren test is enabled, siren alarms for 2 seconds.
If Arm/Disarm from foreign Keypad is enabled, users arm/disarm his/her partitions without interested in
keypad partitions.
Exit delay is extended when enter/exit zone is active if Extendable Exit Delay feature is enabled.
If Double Hit feature is enabled, two alarms from the same zone within cross zone timer duration will cause
panel to go into alarm. Double Hit feature is affects only zones selected as Cross Zone.
If Daylight Saving feature is enabled, panel automatically adjusts system time for daylight saving changes.
Note: Daylight Saving feature is devolped for the European Standarts.
Address= 10 01 . < IP >
To see value :
LED 10 01 (wait)
LCD 1-PANEL SETTINGS → GENERAL SETTINGS → 01-PANEL OPTIONS (wait)
To change value :
LED 10 01 S ........S √
LCD 1-PANEL SETTINGS → GENERAL SETTINGS → 01-PANEL OPTIONS
S ........S √
S = Multiple choice selection(1 6)
Default Value : 2(ON)= Quick Arm enabled, 3(ON)= Automatic siren test is enabled,
5(ON)= Extendable Exit Delay Enabled
Example : To disable Automatic Siren test do
“ 10 01 3(OFF) √ “
o Output Types
SRN, PGM1, PGM2, ARM output types(NC/NO) are configured in this address. Meaning of options is in the
following.