TD-1/07-008
42 / 83
S = Multiple choice selection(1, 2, 3, 5)
Default value : All outputs are NO
Example : To set Siren output as NC do
10 02 5(ON)
o Automatic Bypassed Partitions
If any zone/zones in selected partition are active while arming, that zone/zones is bypassed
automatically(Looka at Zone Extra Settings section). Bypass is cancelled when zone returns normal position.
Meaning of options is in following;
1. option=A partition, 2. option=B partition, 3. option=C partition, 4. option=D partition
S.P.T. : 1.option= Interior, 2.option= Window, 3.option= Door, 4.option= Exterior
It is recommended to select only 1= Interior(Look at page 34 for detailed description).
Address = 10 03 < IP >
To see value :
LED 10 03 (wait)
LCD 1-PANEL SETTINGS GENERAL SETTINGS AUTO BYPASS (wait)
PARTITIONS:
To change value :
LED 10 03 S ........S √
LCD 1-PANEL SETTINGS GENERAL SETTINGS AUTO BYPASS
PARTITIONS: S ........S √
S = Multi choice selection(1,2,3,4)
Default value : No Automatic Bypassed Partitions
Example : To activate automatic bypass feature of A partition do
10 03 1(ON)
o Reset Type
You select what type of reset you will do. Meaning of options is in the following.
1. option = Reset codes, 2. option = Reset Panel Settings(*)
Note(*):Panel settings can only be selected on installer program
Address = 10 04 < IP, MP >
To see value :
LED 10 04 (wait)
LCD 1-PANEL SETTINGS GENERAL SETTINGS DEFAULT SET REQ (wait)
To change value :
LED 10 04 S ........S √
LCD 1-PANEL SETTINGS GENERAL SETTINGS DEFAULT SET REQ
S S √
S = Multiple choice selection(1,2)
Default Value : Options are closed
Example : To reset codes and panel settings do
10 04 1(ON) 2(ON)
o Reset Enable/Disable
Installer can disable reset permissions. Meanings of options are in the following;
1. option = Reseting Codes, 2.option= Reseting Panel Settings
Address = 10 06 < IP >
To see value :
LED 10 06 (wait)
LCD 1-PANEL SETTINGS GENERAL SETTINGS RESET PERMISSION (wait)