5. PROGRAMMING SETTINGS
5.1. INTRODUCTION
VAP404 has two programming sections. One of them is Installer Program<IP> that is entered by installer
code other is Master Program<MP> that is entered by master code. Installer program includes addresses,
and operational settings that are used by technician who installs panel. Master program includes addresses
that are interested in user settings like time/date, phone numbers, user passwords and permissions.
Passwords can be reset in master or Installer program. Settings in master or installer program can be reset
only in Installer program.
To programming, enter address of feature you want configure. If you wait a little, you see value in that
address. At this moment you can enter new value and then press .
Programming addresses are classified in VAP404. Addresses are total 4 digits. First two digits of addresses
indicate address group. The second two digits of addresses indicate zone no, user no, keypad no…etc.
Main configurations include addresses that are used in basic installations so installer easily installs system.
Main Settings : 01-Date/Time
02-Partition Entry Delays
03-Partition Exit Delays
04-Central Monitoring Station Account Numbers
05-Central Monitoring Station Phone Numbers
06-User Phone Numbers
07-User Codes
Panel Settings: 10-Panel General Settings
11-Siren Settings
12-Automatic Arm-Disarm
13-PGM Settings
14-Timer Settings
15-Remote Access(by telephone)
16-KEY Settings
Zone Settings: 20-Zone Wiring
21-Zone Partition
22-Zon Type
23-Zon Settings
24-Zone Trigger Delay
Keypad Settings: 30-Keypad Permissions
31-Keypad Partitions
99-Keypad Inner Settings
User Settings: 40-Start time
41-Finish time
42-Authorized days
43-Authorized partitions
44-User Keypads
45-User Limitations
Communicator-Dialer: 50-General Settings
51-Reporting Settings
52-53-Central Monitoring Station Event Codes
Optional Modules: 60-RF Remote Controller Settings
61-Zone Expander Module Settings