TD-1/07-008
37 / 83
DATE:
To change value :
LED 01 02 GG AA YY √
LCD 0-BASIC SETTINGS CLOCK SETTING CLOCK SETTING
DATE: dd mm yy √
dd = day, mm = month, yy = year
Default value : 00/00/00
Example : To set date as 15 October 2004 do 01 02 15 10 04
o Day of week
Address: 01 03 < IP, MP >
To see value :
LED 01 03 (wait)
Day of week : 1=Monday, 2=Tuesday,......, 7=Sunday (single choice)
Default value : 1= Monday
Note: This address is only readable. Panel sets date automatically. LCD Keypad displays date on screen.
8.1.2. Entry Delays
This setting gives selected partition enter delay. Follower zone must be in same partition with delayed
zone(Look at Zone Settings).
o Enter Delay of A Partition
Entr y delay of S.P.T. is configured here.
Address = 02 01 < IP >
To see value :
LED 02 01 (wait)
LCD 0-BASIC SETTINGS → ENTER DELAYS → 01-PART ENT DLY(wait)
To change value :
LED 02 01 w w w √
LCD 0-BASIC SETTINGS → ENTER DELAYS → 01-PART ENT DLY
w w w SECOND(S)
w w w = enter delay(second) , (between 0 ~ 255 seconds)
Default value : 15 seconds
Example : To set enter delay of A partition to 20 seconds do 02 01 20 √ “
o Enter Delay of B Partition
Address= 02 02 < IP >
Default value : 0 second
o Enter delay of C Partition
Address : 02 03 < IP >
Default value : 0 second
o Enter Delay of D Partition
Address : 02 04 < IP >
Default value : 0 second
8.1.3. Exit Delays
This setting gives selected partition exit delay. Follower zone must be in same partition with delay zone(Look
at Zone Settings).
o Exit Delays of A Partition
Exit delay of S.P.T is configured here.
Address= 03 01 < IP >
To see value :
LED 03 01 (wait)
LCD 0-BASIC SETTINGS EXIT DELAY 01-PART EXIT DLY (wait)
To change value :
LED 03 01 w w w √