TTT : Time between 0-255 seconds.
Default : 60 seconds
Sample : To set cross zone time as 40 sec. do 10 09 40.
8.2.2. Siren Settings
o Siren Partitions
Siren doesn’t alarm if alarm comes from unselected siren partition.
1. option=A ppartition, 2. Option=B partition, 3. Option=C partition, 4. Option=D partition
S.P.T. : 1.option= Interior, 2.option= Window, 3.option= Door, 4.option= Exterior
It is recommended to select all partitions on S.P.T.(Look at page 34 for detailed description)
Address = 11 01 < IP >
To see value :
LED 11 01 (wait)
LCD 1-PANEL SETTINGS → SIREN SETTINGS → 01-SIREN (wait)
PARTITIONS:
To change value :
LED 11 01 S.........S √
LCD 1-PANEL SETTINGS → SIREN SETTINGS → 01-SIREN
PARTITIONS: S ........S √
S = Multiple choice selection(1, 2, 3, 4)
Default Value : 1=A partition, 2=B partition, 3=C partition, 4=D partition
Example : To disable siren for 3. partition do
“ 11 01 3 (OFF) √ “
o Siren Cut off Time
Address = 11 02 < IP >
To see value :
LED 11 02 (wait)
LCD 1-PANEL SETTINGS → SIREN SETTINGS→ CUT OFF TIME (wait)
To change value :
LED 11 02 R R R √
LCD 1-PANEL SETTINGS → SIREN SETTINGS → CUT OFF TIME
R R R MINUTE(S) √
RRR = 3 digit cut off time ( 2~255 minutes )
Default value : 5 minutes
Example : To set siren cut off time to 12 minutes do
“ 11 02 12 √ “
8.2.3. Automatic Arm/Disarm Settings
Panel can automatically arm/disarm panel in specific time of day.
o Automatic Arm Partitions
Selected partitions in this address are automatically armed. To disable automatic arm feature, unselect
partitions. Meanings of options are in the following.
1.option = A partitions, 2. option=B partitions, 3. options=C partition, 4. options=D partition
S.P.T. : 1.option= Interior, 2.option= Window, 3.option= Door, 4.option= Exterior
It is recommended to select all partitions on S.P.T.(Look at page 34 for detailed description)
Address = 12 01 < IP >
To see value :
LED 12 01 (wait)
LCD 1-PANEL SETTINGS → AUTO ARM/DISARM → AUTO ARM (wait)
To change value : PARTITIONS:
LED 12 01 S ........S √