HD3G7 HD 3 Gb/s SDI Video Generator module
STATUS. Displa
ys the instrument operating mode, output signal format, and
output sample structure. (See page 3 -190, HD3G7 module STATUS menu.)
OUTPUT MODE. Selects the mapping format o f the output signal to Level A
(direct image format mapping), Level B ( SMPTE 372M dual link mapping), as
described by SMPTE 425, or HD-SDI.
Within Level A and Level B there are also selections for 1920 × 1080, 2K ×
1080, and 1280 × 720 (Level A only) formats. Also, for Level B only, there are
selections for 2×HD 1920 × 1080 and 2×HD 1280 × 720 formats. The 2×HD
mode produces two standard HD streams in the same format (e.g. 1080). Select
between Test Signal/Test Signal or Test Signal/Black for the two streams. (See
page 3-191, HD3G7 module OUTPUT MODE submenu.)
SAMPLE STRUCTURE/DEPTH. When the output mode is set to a
non-fast-progressive format, the SAMPLE STRUCTURE/DEPTH menu is
available. There are several sample structures to choose from. Press the left ()
or right () arrow buttons to scroll through the available options. When the
desired sample structure is displayed, press the ENTER button to select it.
3G non-fast progressive formats (1080 line)
RGB 444 12b YCbCr 444 10b
RGB 444 10b YCbCrA 444 10b
RGBA 444 10b YCbCr 422 12b
YCbCr 444 12b YCbCrA 422 12b
(Level B mapping only)
3G fast progressive format (1080 line)
YCbCr 422 10b
3G formats (720 line)
RGB 444 10b YCbCr 444 10b
RGBA 444 10b YCbCrA 444 10b
2×HD formats (1080 and 720 line)
YCbCr 422 10b
2K line formats
XYZ 444 12b
RGB 444 12b
HD format
YCbCr 422 10b
ALPHA CHANNEL DATA. Selects the data to be placed on the alpha channel when
a sample structure that include s an alpha channel is selected. The channel can
contain a duplicate of the Y or G channel data or a at eld signal. This menu
item appears only when the sample structure is set to “+A” for 3G signal formats.
Use the left ()orright()arrowbuttontoselectUse Y/G Channel or to
select a 0% to 100% Flat Field in 10% increments, and then press the ENTER
button to enable the selection.
3–188 TG8000 Multiformat Test Signal Generator User Manual

Table of Contents

Other manuals for Tektronix TG8000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TG8000 and is the answer not in the manual?

Tektronix TG8000 Specifications

General IconGeneral
BrandTektronix
ModelTG8000
CategoryPortable Generator
LanguageEnglish

Related product manuals