EasyManua.ls Logo

Thames Side Smart Series - Page 22

Thames Side Smart Series
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation
2-8
Format F8:
<STX> POL ‘ ‘ ppppppp ‘ ‘ Unit Unit ‘ ‘ Mode Mode ‘ ‘ T
UNITS: kg = ‘KG’ MODE: Gross= ‘BR’
lb = ‘lb’ Net= ‘NT’
Format F9:
ppppppp T
Format F10:
<STX> <STA> ppppppp T
<STA>: status, 1 character: "+" positive weight
"-" negative weight
"?" unsteady weight
Format F11:
<STX> ‘ ‘ ‘ ‘ ‘ ‘ POL ppppppp T
Format F12:
<STX> <STA> weight T
<STA>: status, 1 character: "S" steady weight
"N" unsteady weight
weight: without decimal point Æ 6 digits
with decimal point Æ 7 digits
Format F13:
<STX> “ <STA> weight T
<STA>: status, 1 character: "S" steady weight
"N" unsteady weight
weight: without decimal point Æ 5 digits
with decimal point Æ 6 digits
The device only transmits an answer if the conditions of stability are in accordance
with the normative EN45501. If in the moment of the petition of weight there is not
stability, the device leaves the petition in wait until there is stability. There is not a
wait time out.
Definitions:
<STX> Start of Text (ASCII 2)
<ETX> End of Text (ASCII 3)
<ENQ> Enquire (ASCII 5)
<SYN> Synchronous Idle (ASCII 22)
<CR> Carriage Return (ASCII 13)
<LF> Line Feed (ASCII 10)
‘ ‘ Space character
‘0’ Character ‘0’
‘1’ Character ‘1’
ppppppp Weight value, 7 characters

Table of Contents