Thermo Scientific TSQ Series Hardware Manual 115
Index: Q
configuring the LC 15
disassembling the ion optics cage assembly 96
installing the Ion Max API source 71
installing the Ion Max-S API source 71
maintaining the forepump 101
placing system in standby 51
reinstalling the exit lens 89
reinstalling the ion optics cage assembly 99
reinstalling the ion source interface 90
reinstalling the skimmer 89
reinstalling the S-lens 89
reinstalling the tube lens 89
removing skimmer 87
removing the exit lens 86
removing the S-lens 86
removing tube lens 87
resetting mass spectrometer 57
product scan mode
discussed
5
illustration (figure) 6
profile scan, defined 12
pumps
forepump
40
turbomolecular pump 40
Q
Q0 ion optics chamber, location (figure) 39
Q0 ion optics, discussion 27
Q0 mount assembly, location (figure) 96
Q0 quadrupole
description
27
figure 27
Q00 ion optics
cleaning
91
cleaning components 97
cross-sectional view 23
reassembling 98
skimmer 25
Q00 RF lens
description
26
figure 26
on/off status 60
Q00 rf lens
cleaning
91, 97
location (figure) 23
Q00/L0 mount assembly
exploded view (figure)
97
location (figure) 96
Q1 quadrupole, figure 29
Q1MS and Q3MS scan modes 5
Q2 rod assembly, figure 30
Q3 quadrupole, figure 29
quadrupole mass analyzer
functional description
29, 32
quadrupole offset voltage 33
quadrupoles
mass analysis
29, 32
Q0, description 27
Q1 and Q3 29
RF and dc fields (figure) 31
rf and dc fields (figure) 30
R
regulatory compliance iii
replaceable parts
accessory kit
107
fittings 109
part numbers 107
sample loops 109
RF voltage generation, discussion 43
right side power panel
discussion
21
figure 21
rod assemblies
description
30
ion transmission 4
mass analysis 4
mass analyzer(s), quadrupole 29, 32
Q1, Q2, and Q3 (note) 5
roughing pump 40
S
safety precautions xviii
sample loop, replaceable parts 109
sample transfer line, flushing 66
sample tube, flushing 66
scan data types
centroid scan
12
profile scan 12
Scan LED, description 19
scan modes
data-dependent
9
discussed 3
mass spectrometer 3
neutral loss 7
neutral loss, example (figure) 9
neutral loss, illustrated (figure) 8
parent 6
parent, illustrated (figure) 7
product 5
Product, illustrated (figure) 6
Q1MS and Q3MS 5
summary (table) 4

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thermo Scientific TSQ Quantum Access MAX and is the answer not in the manual?

Thermo Scientific TSQ Quantum Access MAX Specifications

General IconGeneral
BrandThermo Scientific
ModelTSQ Quantum Access MAX
CategoryLaboratory Equipment
LanguageEnglish

Related product manuals