TestingtheLiftCircuit–LiftCylinderInternalLeakage(Machine
SerialNumbersabove316000000)
g225190
Figure73
Performaliftcylinderinternalleakagetestifyouidentifyacuttingdeckraiseand
lowerproblem.Thistestdeterminesiftheliftcylinderbeingtestedisdamaged.
Theliftcylindersmustbetestedindividually.
Note:Theraise/lowercircuitoperationcanbeaffectedbytheliftcylinder
binding,extraweightonthecuttingdeck,and/orbindingoftheliftcomponents.
Ensurethattheseitemsarecheckedbeforecontinuingwiththeliftcylinder
internalleakagetest.
HydraulicSystem:TestingtheHydraulicSystem