INPUT/OUTPUT(continued)
Tolowertheleftwingdeck,thefollowinginputsandqualiersarerequired
(Figure153):
•Operatorseatneedstobeoccupied(SEATON).
•High/LowtractionspeedrangeswitchinLOposition(HIGHRANGE
REQUESTOFF).
•HydraulicsolenoidvalveSVshouldbede−energized(HIGHRANGEOFF).
•Leftwingdeckraise/lowerswitchpressedtolower(LEFTDECKLOWERON).
Iftheproperinputsandqualiersexist,thefollowingoutputsshouldoccur
(Figure153):
•HydraulicsolenoidvalveS1shouldbeenergized(MASTERLIFTSOLENOID
ON).
•HydraulicsolenoidvalveS3shouldbeenergized(LEFTDECKLOWERON).
•HydraulicsolenoidvalveS4shouldbeenergized(LEFTDECKFLOATON).
g288317
Figure154
(Float)
Oncethedeckisfullylowered,thedeckshouldoatandfollowingoutputs
shouldoccur(Figure154):
•HydraulicsolenoidvalveS4shouldbeenergized(LEFTDECKFLOATON).
Note:Ifadeckisalreadyfullyloweredwhenthekeyswitchismoved
fromOFFtoRUN,thedeckwillnotbeinoatuntilthedeckraise/lower
switchismomentarilypressedtolower.
ElectricalSystem:InfoCenterDisplay
Page6–24
Groundsmaster
®
5900&5910
16227SLRevB