BatteryInspection,Maintenance,andTesting(continued)
G.Ifthetestvoltageisbelowtheminimumvoltageshowninthechart,
replacethebattery.Ifthetestvoltageisatorabovetheminimum,return
thebatterytoservice.
BatteryCharging
Tominimizepossibledamagetothebatteryandtoallowthebatterytobefully
charged,theslowchargingmethodispresentedhere.Thischargingmethod
canbeaccomplishedwithaconstantcurrentbatterychargerwhichisreadily
available.
CAUTION
Followthebatterychargermanufacturer’sinstructionswhenusing
abatterycharger.
1.Disconnectthebatterycablesfromthebatterybeingchargedbeforecharging
(seeBatteryRemoval(page6–140)andBatteryInstallation(page6–142)).
2.Determinethebatterychargelevelfromitsopencircuitvoltage.
BatteryChargeLevelSpecicGravityOpenCircuitVoltage
100%
1.26512.68
75%
1.22512.45
50%
1.19012.24
25%
1.15512.06
0%
1.12011.89
3.Determinethechargingtimeandrateusingthebatterycharger
manufacturer’sinstructionsorthefollowingtable.
BatteryChargeLevel(PercentofFullyCharged)
Battery
Reserve
Capacity
(Minutes)
75%50%25%0%
80orless
3.8hrs@3amps7.5hrs@3amps11.3hrs@3
amps
15hrs@3amps
81to125
5.3hrs@4amps10.5hrs@4
amps
15.8hrs@4
amps
21hrs@4amps
126to170
5.5hrs@5amps11hrs@5amps16.5hrs@5
amps
22hrs@5amps
171to250
5.8hrs@6amps11.5hrs@6
amps
17.3hrs@6
amps
23hrs@6amps
above250
6hrs@10amps12hrs@10
amps
18hrs@10
amps
24hrs@10
amps
ElectricalSystem:ServiceandRepairs
Page6–144
Groundsmaster
®
5900&5910
16227SLRevB