Removal(Figure345)
g299834
Figure346
1.Condenserfan(2)3.Fanplug(2)
2.Knob(2)
g299835
Figure347
1.Fanmountplate
4.Condenserfan(2)
2.Screw(4perfan)5.Plasticplug(3)
3.Fantab(4perfan)
1.Parkmachineonalevelsurface,lowercuttingdecksandstopengine.
Removekeyfromthekeyswitch.
2.LocateA/Ccondenserfanassemblywhichissecuredtotheframeunder
therearofthecabheadliner.
3.Disconnectthetwo(2)condenserfanplugsfromthewireharnessconnectors
attachedtothecabframe(Figure346).
4.Supportthecondenserfanassemblytopreventitfromfalling.
5.Removetwo(2)knobsthatsecurecondenserfanassemblytomachine
(Figure346).
6.Lowercondenserfanassemblyfrommachine.
7.Ifnecessary,disassemblecondenserfanassemblyusingFigure347as
aguide.