AUTOMATIC DUPLEXING UNIT (ADU)
17 - 10
17.6 Flow Chart
A
Yes
No
Yes
No
Yes
No
Exit motor reverse
rotation ON
Specified time
has passed
Specified time
has passed
ADU motor ON
ADU motor ON
ADU clutch ON
ADU transport jam (E510)
ADU transport jam (E520)
ADU motor stopped
ADU entrance
sensor ON?
ADU exit sensor
check the arrival?
Trailing edge of
first paper turned
OFF the ADU exit
sensor?
Specified time has passed
(Paper is transported to the first stopping
position in ADU)