e-STUDIO556/656/756/856(Ver03) © 2012 TOSHIBA TEC CORPORATION All rights reserved
DISASSEMBLY AND REPLACEMENT
4 - 64
4.7.5 Cleaning brush
4.7.6 Image quality sensor (S14)
1. When replacing the recovery blade, be
sure to separate it completely because it
is attached with the two-sided adhesive
tape.
2. Attach the recovery blade by pushing its
lower edge against the step of the cleaner
frame. (A in the figure on the right)
Fig. 4-180
(1) Take off the drum.
( P.4-61 "4.7.2 Drum thermistor (THM5)
and Drum")
(2) Pull out the shaft held on the rear side to take
out the cleaning brush.
Fig. 4-181
(1) Take off the cleaner unit.
( P.4-61 "4.7.1 Cleaner unit")
(2) Disconnect 1 connector and remove 2
screws to take off the image quality sensor.
Fig. 4-182
Recovery blade
Cleaner flame
Drum
(
A
)
Cleaning brush
Holding shaft