4
© 2012 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO556/656/756/856(Ver03)
DISASSEMBLY AND REPLACEMENT
4 - 25
4.3.13 Carriage home position sensor (S6)
4.3.14 Scan motor (M1)
(1) Take off the top left cover.
( P.4-2 "4.1.5 Top left cover")
(2) Remove the protection sheet.
(3) Disconnect 1 connector to take off the
carriage home position sensor.
Note:
When the sensor has been replaced, be sure
to put a new protection sheet.
Fig. 4-68
(1) Take off the top rear cover and the rear
cover.
( P.4-3 "4.1.6 Top rear cover", P.4-5
"4.1.13 Rear cover")
(2) Remove 1 screw and releasse the 2 clamps.
(3) Remove 4 screws and take off the bracket[1].
Fig. 4-69
(4) Release the harness from the harness
clamp.
(5) Remove 3 screws and take off the scan
motor with the whole bracket.
Note:
hen installing the scan motor, be sure to
perform the belt tension adjustment.
Fig. 4-70
Carriage
home position sensor
[1]
Screw
Scan motor

Table of Contents