REPLACEMENT OF PC BOARDS / HDD
9 - 29
9.2.8 Firmware confirmation after the PC board/HDD replacement
After replacing the PC board/HDD, check the firmware version in the setting mode (08) and confirm if
the firmware combination is correct.
* If “NGD” is displayed for the PFC ROM. version (08-9940), the downloading of PFC ROM fails.
Update the firmware again.
P.11-51 "11.7 When Firmware Updating Fails"
Firmware Code Remarks
Updating Master data
(HDD program data)
08-8952 HDD data External version
08-9900 System software version
Updating System ROM
(OS data)
08-9930 System ROM version
Updating Laser ROM 08-9941 Laser ROM version
Updating Engine ROM 08-9901 Engine ROM version
Updating Scanner ROM 08-9902 Scanner ROM version
Updating PFC ROM 08-9940 PFC ROM version
Updating RADF ROM 08-9903 RADF ROM version
Updating Finisher ROM 08-9904 Finisher ROM version
Saddle stitcher ROM version
Updating Inserter ROM 08-9942 Inserter ROM version
Updating FAX ROM 08-9905 FAX ROM version