ADJUSTMENT
6 - 3
Fig. 6-5
(6) Press the [OK] or [INTERRUPT] button. The drum, developer unit, etc. are stopped and the
following is displayed.
The drum, developer unit, etc. are stopped and the following is displayed.
Fig. 6-6
(7) Standard of adjustment value range
(8) Key in code [2120] and press the [START] button. When the message "WAIT" goes off, turn the
power OFF by shutdown.
(9) Install the toner cartridge.
Humidity(%) Adjustment reference voltages (V)
0 to 29.9 2.46
30.0 to 44.9 2.48
45.0 to 59.9 2.50
60.0 to 74.9 2.64
75.0 to 100 2.78
240%
128
2000
ADJUSTMENT MODE
A3
150
A
B
[OK]
or
[
INTERRUPT
]
100%
TEST MODE
A3
A