6
© 2012 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO556/656/756/856(Ver03)
ADJUSTMENT
6 - 5
[Procedure to key in adjustment values]
In accordance with the procedure described below, make adjustment of each adjustment item so that
the measured values obtained from test copies satisfy the specification. By pressing the [FAX] button,
immediately after starting the Adjustment Mode (05), single-sided test copying can be performed
(normal copy mode).
Fig. 6-7
0
1
5
POWER
ENTER
INTERRUPT
Digital keys
START
: Enter codes.
<Operation keys> <Display>
Current adjustment value
Adjustment value newly entered
(If no entering, YYY is displayed.)
Power OFF/ON
: Exit the Adjustment Mode.
Test copy
Digital keys
: Enter adjustment
values.
Value ZZZ is stored
replacing values YYY.
If the test copy does not
satisfy the specified values,
return to step 1 and
repeat the adjustment
procedure.
or
( CLEAR Use to make corrections)
100%
AA3
TEST MODE
100%
AA3
TEST MODE
100%
AA3
Wait Warming Up
100%
AA3
COPYING
Code No.
100%
YYY ZZZ
XXXX A3
TEST MODE
FAX
START