6
© 2012 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO556/656/756/856(Ver03)
ADJUSTMENT
6 - 103
• The center of the printed image shifts to the rear side:
Move the adjustment board to the rear side (Arrow (A) in the upper figure).
Fig. 6-122
After the tray position adjustment, re-adjust the front cover position. Adjustment: loosen 4
screws and slide the front cover to adjust the gap between the front and upper cover, and the
front and right cover to 3 mm respectively.
Fig. 6-123
Feeding direction
Center
[
Rear
]
[
Front
]
Front cover