ERROR CODE AND TROUBLESHOOTING
8 - 101
[CA30] Secondary scanning coarse adjustment error [e-STUDIO756/856]
[CA41] Window comparator abnormality (error during secondary scanning control)
[e-STUDIO756/856]
[CA42] Sensor signal busy error (error during secondary scanning control) [e-STUDIO756/856]
[CA43] Comparator abnormality [e-STUDIO756/856]
[CA50] Laser power adjustment error [e-STUDIO756/856]
[CAA0] Secondary scanning fine adjustment error [e-STUDIO756/856]
[CAB0] Inter-page correction error of secondary scanning [e-STUDIO756/856]
[CAC0] Primary scanning dot adjustment error [e-STUDIO756/856]
[CAF0] Inter-page correction error of primary scanning [e-STUDIO756/856]
[CD00] Laser initialization time-out [e-STUDIO756/856]
[CA90] Image data transmission error of SYS board
Is any harness between the PLG board and galvanic mirror, PLG board and laser drive PC
board and PLG board and H-Sync detection PC board open circuited or any connector
disconnected?
YES Replace the harness. Reconnect the connector.
NO
1. Replace the PLG board.
2. Replace the laser optical unit.
Is the harness between the PLG and SYS boards open-circuited or the connector
disconnected?
YES Replace the harness. Reconnect the connector.
NO
1. Replace the PLG board.
2. Replace the SYS board.