e-STUDIO556/656/756/856(Ver03) © 2012 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND TROUBLESHOOTING
8 - 108
[CBC0] Alignment motor abnormality
[CBD0] Guide motor abnormality
Is the alignment plate home position sensor (PI5S) working normally?
NO Replace the sensor.
YES
Is the alignment motor (M5S) operating at the fixed timing?
YES Replace the saddle stitcher controller PC board.
NO
Is the alignment plate drive mechanism normal?
NO Fix the mechanism.
YES
Is the problem solved by replacing the alignment motor (M5S)?
NO Replace the saddle stitcher controller PC board.
YES
END
Is the guide home position sensor (PI13S) working normally?
NO Replace the sensor.
YES
Is the guide motor (M3S) operating at the fixed timing?
YES Replace the saddle stitcher controller PC board.
NO
Is the guide plate drive mechanism normal?
NO Fix the mechanism.
YES
Is the problem solved by replacing the guide motor (M3S)?
NO Replace the saddle stitcher controller PC board.
YES
END