DISK FULL NOTIFICATION
14-8 Installation Manual June, 2011
DISK FULL NOTIFICATION Under some conditions the server disk can become full. Use the following
procedure to setup an email alert to the system administrator when the
disk is 80% full.
1. Using Enterprise Manager, select Applications > Messaging. In the
Messaging administration screen select Registry > Alerts.
2. Under Administration, enter the name of the Mail Server.
3. Enter the email address for the administrator where the alerts should
be sent.
4. Under Maximum Disk Usage Alert, ensure that HD Used is checked
and set at 80 for the Administrator to receive an email notification
when the hard disk is 80% full (default setting).
5. HD Used Repetitions – Enter the number of times for the
Administrator is to be notified via email.
6. Check Database Error Message. Enter the value %s (default setting).

Table of Contents