Loading...
EC SERVER Input Power
2-2 Installation Manual June, 2011
Operating Relative Humidity: 8% to 90% (non-condensing)
Input Power 100 ~ 240 VAC, 50 ~ 60 Hz
Peak load: 130 W, 1.2 Amp at 120 VAC (tested)
Maximum Inrush Current: 11.5 Amp
Figure 2-2 IPedge EC Server Front Panel
Figure 2-3 IPedge EC Server Rear Panel Connections
EC Front Panel The front panel of the IPedge EM server has push-button switches and
LED indicators. The disk drive is accessible from the front.
The power supply is accessed through the rear panel. All cable
connections are on the rear panel.
Buttons Power On/Off Button - This applies or removes system power. When the
power is turned off using this button main power is shut off but standby
power to the system remains on. To completely remove power from the
system use this button to shut down the system then, disconnect the AC
power cord.
Power Up Sequence: Set the rear panel power switch to ON. Wait one
minute then, press the font panel power button.
System Reset Button - Press and release to reset then, reboot the
server.
LEDs Power LED - Indicates that system power is on when Illuminated.
System Reset
Power On/Standby
System Power LED
Network Activity (2)
Hard Disk Activity
USB Connectors
Keyboard
PS/2 Mouse
USBAC Power
NIC 2
NIC 1
VGACOM 1
IPMI