EM SERVER POWER SUPPLY REPLACEMENT Restore Database
15-8 Installation Manual June, 2011
26. Verify that the OS boot Watchdog Timer is Disabled. If it is disabled
go to Step 28. If it is Enabled, Highlight Disabled then, press the
Enter key.
27. Highlight Yes then, press the Enter
28. Press the F10 key.
29. The system will restart.
The system has been returned to its as-shipped condition. Remember
that the IP addresses, User Names and Passwords are reset to thier
default values.
Restore Database If a backup file is available use the following outline.
1. Refer to Chapter 4 – System Installation in this manual for the
procedures required to set the server name and IP addresses.
2. If this is a stand-alone server or Primary node go to Step 5. If this is a
Member node go to Step 3.
3. After the new system setup steps. Change the server to Member
status.
4. Access the restored server from the Primary server Enterprise
Manager.
5. Apply all licenses.
6. Restore the database. Refer to Chapter 7 – IPedge System Backup
in the “MANUAL RESTORE” on page 7-6 section.
7. Synchornize the database.
EM SERVER POWER
SUPPLY REPLACEMENT
You do not need to shut down the system to replace an EM server power
supply module. The redundant power supply feature will keep the system
up and running while you replace the failed hot-swap module. Replace
the power supply module with the same model, which can be ordered
from Toshiba.
1. The failed power supply led will change from green to amber. First
unplug the power cord from the failed power supply module.
2. To remove the failed power module, push the release tab (on the back
of the power supply) to the side and then pull the module straight out.
Refer to Figure 15-1.
3. The power supply wiring was designed to detach automatically when
the module is pulled from the chassis.
4. Replace the failed power module with another PWS-651-1R power
supply module.
5. Simply push the new power supply module into the power bay until
you hear a click.
6. Finish by plugging the AC power cord back into the module.