134
6 F 2 S 0 7 1 5
Displaying Impedance Value
This part describes how to display the impedance values for 1 cycle before the active cursor
position.
Note for Operation
Select phase order before operating.
(2.1 Setting Parameters for Measurement and Analysis Selecting Phase Order)
You can select the primary values or the secondary values for the impedance values.
You can select the leading display or delay display for the phase differences.
(2.1 Setting Parameters for Measurement and Analysis Selecting Options)
Operating Procedure
Display the active cursor at the measurement point.
On the [Analysis] menu, click [Impedance].
The impedance values of the current phase order setting are displayed.
The impedance values for 1 cycle before the cursor position are calculated.
The phase differences between the vectors of the real number and the vectors of the imaginary number
are displayed.
You can update the values by moving the cursor.
[--------] is displayed where it can not be analyzed.