r.o::iou::i
1 o
Grcq>
Function
Tiiie
Adjustment
range
Resolution
Detmt
Re-
marks
G.-.02
RR
input
selection
,-
.-
:.-.
I
a:
Standard
-
1
Gr.SF
I
Fan
I
1 :
Adjustable
I
-----,----------------------
----------1---
----------------------------
----------
1-------
1 :
RR
reference
point
#1
p I •
a-10a
1
o/o
a
:RR
point
#1
frequency
F-P
'
.
a-maximum
frequency
a.11a.a1
Hz
a.o
'
I
P2
:
RR
reference
point
#2
.
a-1ao
1
o/o
1ao
:
RR
point
#2
frequency
F-P2
.
a-maximum
frequency
0.1/0.01
Hz
6a.o
IV
input
selection
'
:.-.
•u
a:
Standard
-
1
Gr.SF
-----T----------------------
_________
,.
__
_1..;_~~j~~~~~-----------------
---------
-------
1 :
IV
reference
point
#1
P3
: •
a-1ao
1%
20
:
IV
point
#1
frequency
F-P3
I
a-maximum
frequency
a.11a.a1Hz
a.a
I
.
I
I
:
IV
reference
point
#2
PY
I
a-100
1
o/o
1aa
I •
:
IV
point
#2
frequency
F-P'-:
I
: .
a-maximum
frequency
a.1/a.01Hz
6a.a
Preset
speed
selection
-~..C.;!'.!
__
J__
a:
disabled
1-15:
speeds
(1-15)
-
a
Gr.SF
-----,----------------------
s.-.n
I
~---------------------------
----------
------
Other
:
Mode
selection
I •
a:
deactivated
-
a
I
than
I
I
1:
activated
I
I
1----------------------
---------,--
~---------------------------
----------
------
a
:
1st
speed
5,-0
I : *
Lower
limit
frequency-upper
limit
0.1/0.01
Hz
0.0
I
I
~~~g~~~~~-------------------
I
I
•----------------------
----------+--
----------
------
:
1st
speed
run
mode
5.-.'1 I : *
a:Acc/dec
#1,
V/F
#1,
forward
run
0
I
I
I
I
+
1:
Reverse
run
I
I
I
I
+2:
Ace/dee
#2
I
I
I
I
I
I
+4:
V/F
#2
I
I
~----------------------
---------r--
--------------------------------------
-------
:
(Up
to
15th
speed
omitted)
I
Emergency
stop
selection
ESl=P
I
O:
Coast-stop
-
a
Gr.Pr
I
I
I
1 :
Decelerated
stop
I
I
2:
DC
injection
stop
I
--2---:-E"sror-ocirij6C1iontime-
_________
_i_
__
~5:::10----------------------
---------
------
Edbl=
: •
0.1
sec.
0.1
Retry
selection
.-1=
,-
'=I
I
0:
no
retry
function
-
0
Gr.Pr
I
I
1-10:
1-10
times
I
-----,----------------------
_________
_i_
__
~---------------------------
---------
------
Other
:
Retry
time
setting
.-1=
I=
I
0.0-10
0.1
sec.
1.0
I •
I
than
I
I
I
I
I
I
0
I
I
I
Regeneration
power
ride-through
I I
,-
I
a:
OFF
-
1
Gr.Pr
UUL.
I
I
control
I
1:
ON
I
--1--TR"iCie:i~iraG91itime
_______
-L:::.i-t-t-T:-
~o:if.::.25---------------------
---------
-------
0.1
sec.
2.0
Auto-restart
(Motor
speed
search)
F:,-sc
I
O:OFF
3
Gr.Pr
1:
On
momentary
power
failure
2:
On
ST
make/break
(commercial
power
switching)
3:
Both
1
and
2
Motor
overload
protection
level
1=
,'-:
,-
'
10-100%/A
1%/A
10a
Gr.Pr
'
OL
reduction
start-up
frequency
DLF
0-30
0.1/0.01Hz
30.0
Gr.Pr
OL
selection
.-
..
,-,
Uc_
I I
a:
Standard
-
0
Gr.Pr
+ 1 :
Soft-stall
ON
+2:
OLM!
trip
OFF
Stall
protection
Sl=C
'
O:ON
-
a
Gr.Pr
'
_________
..J__
1:0FF
-----,----------------------
----------------------------
----------
------
a :
Stall
protecton
level
(current
Sl:L
'
I
10-215%/A
1
%/A
15a
'
I
.
I
:
limit
level
adjustment)
I
I
-137-