EasyManuals Logo

Toshiba Tosvert VF-A5 User Manual

Toshiba Tosvert VF-A5
157 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #144 background imageLoading...
Page #144 background image
Gro141
Function
Title
Adjustment
range
Resolution
Default
R~
marks
C.-.02
Feedback
control
selection
FbP
I
I
0:
No
feedback
control
-
0
Gr.
Fb
,
I
Fan
I
1:
PIO
control
I
I
I
2:
Speed
feedback
control
-----~----------------------
--------+--
1~RR"in-P'"Ui
__________________
---------
------
1
•2
:
Feedback
input
signal
F b
:,-,
I
-
2
:selection
2:
IV
input
I
I
3:
RX
input
I
I
4:
PG
feedback
(option
board)
I
I
I
5:
RS232C
input
I
I
I
6:
Communication/12-bin.
opt.
I
I
!~!3~~j~p~~-----------------
I
L----------------------
c;rs-----:
:-
----------
:
Proportional
gain
O.D1-2.55
0.01
0.30
·----------------------
----------+---
---------------------------
----------
1-------
:
Integral
gain
[,
I : *
0.01-360.0
0.01s
5.0
:A"n"t~ii~iitiiig_g_aiii
________
---------
..
--
---------------------------
----------
GR
I*
0.0-25.5
0.1s
0.0
·----------------------
----------'---
--------------------------- ----------
1-------
:
Lag
time
constant
GFS ·
0-255
1
80
FM
terminal
function
selection
FnSL
0-16
-
0
Gr.AM
Refer
to
the
standard
parameter
list
for
details.
Frequency
meter
adjustment
Fn
- -
-
Gr.AM
AM
terminal
function
selection
Rn
SL
0-16
-
3
Gr.AM
Refer
to
the
standard
parameter
list
for
details.
Ammeter
adjustment
Rn
- -
-
Gr.AM
The fan application data initial settings that differ from standard settings are as follows.
Group
Function
Trtle
Default
R~
marks
C.-.F
Maximum
frequency
FH
60.0
-
Upper
limit
frequency
I
II
WL.
60.0
-
V/F
pattern
Pt
2 -
c.-.s1=
Output
terminal
0
(RCH)
function
01=0
46
Gr.
02
selection
Output
terminal
1
(LOW)
function
01=
I
48
Gr.
02
I
selection
[,,-.SF
RR
input
,-,-
:.-.
1
Gr.
02
-----T----------------------
1
RR
point
#2
frequency
7=-:~
0
2----
60.0
IV
input
I
:.-,
1
Gr.
02
IL.I
--1--Tiv-point#2-frequency
_____
7=-:~6--C;
____
60.0
[,,-.P,-
Regeneration
power
ride-through
I I
,-
1
Gr.
02
UUL.
control
Auto-restart
(Motor
speed
search)
R,-
51=
3
Gr.
02
c.-
.LJI=
Blind
function
selection
bl
.-.c:
1
-
-----,----------------------
t;Co~·----
------
1
:Industrial
Application
1
:
Parameters
(Fan)
-138-

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba Tosvert VF-A5 and is the answer not in the manual?

Toshiba Tosvert VF-A5 Specifications

General IconGeneral
BrandToshiba
ModelTosvert VF-A5
CategoryInverter
LanguageEnglish

Related product manuals