E6582175
F-134
6
6.34.8 Cancel the operation command
f719 : Selection of operation command clear
Function
This parameter allows you to select operation command retained or operation command cleared, when
coast stop occurs due to standby terminal function (ST), coast stop command terminal function (FRR),
and when under voltage in main circuit alarm (
moff) occurs, during panel operation or RS485
communication operation.
Parameter
setting
At coast stop
At under voltage
in main circuit alarm (
moff)
comd
is changed

Operation command
cleared
Operation command retained

Operation command retained

Operation command cleared
Operation command
retained

Operation command cleared
Operation command retained :
Inverter restarts due to clearing coast stop at coast stop.
Inverter restarts due to supply power source again when the under voltage in main circuit alarm ()
occurs.
Operation command cleared :
Inverter doesn’t restart after coast stop or occurring the under voltage in main circuit alarm ().
Press RUN key to operate again in panel operation.
Switch to ON the operation command in RS485 communication operation.
Title Function Adjustment range Default setting
f719
Selection of operation
command clear
0: Clear at coast stop and retained at
moff.
1: Retained at coast stop and
moff.
2: Clear at coast stop and
moff.
3: 2+ clear when
cmod is changed
1
[Setup example of input terminal]
When it is assigned to the RES terminal.
Title Function Adjustment range Setting
f113
Input terminal selection 3A
(RES)
0-203 6: ST (Standby)
f113
Input terminal selection 3A
(RES)
0-203 96: FRR (Coast stop command)
Setting value 7, 97 are reverse signal.

Table of Contents

Other manuals for Toshiba Tosvert VF-S15

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba Tosvert VF-S15 and is the answer not in the manual?

Toshiba Tosvert VF-S15 Specifications

General IconGeneral
CategoryInverter
Control MethodV/f control, Sensorless vector control
Cooling MethodForced air cooling
ModelTosvert VF-S15
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat
Communication OptionsModbus RTU
Overload Capacity150% for 1 minute
Braking UnitBuilt-in braking transistor
Output Voltage3-Phase, same as input voltage
Operating Temperature-10 to +50°C (14 to 122°F)
Storage Temperature-20 to 65°C (-4 to 149°F)
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000m above sea level
Input Voltage3-Phase 200 to 240 VAC, 3-Phase 380 to 480 VAC
WeightVaries depending on model (e.g., 0.8 kg to 16 kg)