E6582175
D-15
4
psel =0
* When the power is turned on, the inverter is in standard mode. Press the EASY key to switch to easy setting
mode.
psel =1
* When the power is turned on, the inverter is in easy setting mode. Press the EASY key to switch to standard
mode.
psel =2
* Always in easy setting mode.
However, it can be switched to standard setting mode by EASY key if it is set to psel=0, 1. When psel is
not displayed in Easy setting mode, undo is displayed and it can be temporarily switched to standard setting
mode by EASY key after center of the setting dial is pushed for five seconds or more.

Table of Contents

Other manuals for Toshiba Tosvert VF-S15

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba Tosvert VF-S15 and is the answer not in the manual?

Toshiba Tosvert VF-S15 Specifications

General IconGeneral
CategoryInverter
Control MethodV/f control, Sensorless vector control
Cooling MethodForced air cooling
ModelTosvert VF-S15
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat
Communication OptionsModbus RTU
Overload Capacity150% for 1 minute
Braking UnitBuilt-in braking transistor
Output Voltage3-Phase, same as input voltage
Operating Temperature-10 to +50°C (14 to 122°F)
Storage Temperature-20 to 65°C (-4 to 149°F)
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000m above sea level
Input Voltage3-Phase 200 to 240 VAC, 3-Phase 380 to 480 VAC
WeightVaries depending on model (e.g., 0.8 kg to 16 kg)