150
9 SUPPLEMENTS
150
SUPPLEMENTS
Chapter
9
Error release
- Common to load errors and displacement errors
- Load errors
- Displacement error
Error Error release
Perform zero calibration within the zero calibration range.
Perform actual load calibration within the actual load calibration range.
Or, perform equivalent input calibration within the equivalent input calibration
range.
Bring the sensor input into the signal input range/internal count range.
Load : Make the load indicated value -9999 to +9999.
Displacement : Make the displacement indicated value -9999 to +32000.
Error Error release
After the indicated value falls within the set Overload value, turn OFF ON the
Reset input, or press on the Main screen.
Turn OFF ON the Reset input, or press on the Main screen. Or, turn
the power off and then on again.
Error Error release
Turn OFF ON the Reset input, or press on the Main screen. Or, turn
the power off and then on again.