99
5 COMMUNICATIONS
99
COMMUNICATIONS
Chapter
5
- Wave No. read command
- Wave No. write command
* The wave No. is accepted when the Start signal is turned from OFF to ON.
STX 94A2 813576
F381A’s return
(In normal processing)
Header (If there is no header, no data will result.)
0
Host
(Transmission to the F381A)
A Delimiter
84657901 2 3 Delimiter
Alphanumeric characters and symbols from 1 to 20 digits
Setting range (20H to 7EH, 80H to FCH)
STX DelimiterN1G
F381A’s return
(In abnormal condition)
Header (If there is no header, no data will result.)
NG No.
1: Receipt of a statement different from the command format
STX
94A2 8135760
F381A’s return
(In normal processing)
Header (If there is no header, no data will result.)
Host
(Transmission to the F381A)
STX
Delimiter
N1G
F381A’s return
(In abnormal condition)
Header (If there is no header, no data will result.)
NG No.
1: Receipt of a statement different from the command format
2: Attempt to write a set value outside the setting range
Command received by the F381A
94A2 8135760 8465790123
Delimiter
Alphanumeric characters and symbols from 1 to 20 digits
Setting range (20H to 7EH, 80H to FCH)
8465790123