5 COMMUNICATIONS
91
COMMUNICATIONS
Chapter
5
- Hold result read command
Example: Reading the hold results of Section 1 to 3.
① Check to see if measurement is finished
If "1" is read to Waveform update, go to step ②, and if "1" is not read, repeat step ①.
(For transmitting the SAMPLE command continuously, do it at intervals of 100ms or more.)
Host
F381A’s return
(In normal processing)
(Transmission to the F381A)
(
STX
)
Delimiter
0LSM 3APE11
PELSAM
Delimiter
Undefined
Work No. used for measurement
Header (If there is no header, no data will result.)
Waveform update
0: Not made
1: Made
(If an update is made, this bit changes
from 0 to 1 only once upon reading.)
518
Equipment ID
* Equipment ID is a parameter.
(It can be set from the touch panel only
when the SD card slot option/Ethernet option
is mounted.)
(
STX
)
Delimiter
N1G
F381A’s return
(In abnormal condition)
Header (If there is no header, no data will result.)
NG No.
1: Receipt of a statement different from the command format