EasyManua.ls Logo

Unipulse F381A - Hold Result Read Command

Unipulse F381A
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
91
5 COMMUNICATIONS
91
COMMUNICATIONS
Chapter
5
- Hold result read command
Example: Reading the hold results of Section 1 to 3.
Check to see if measurement is finished
If "1" is read to Waveform update, go to step , and if "1" is not read, repeat step .
(For transmitting the SAMPLE command continuously, do it at intervals of 100ms or more.)
Host
F381A’s return
(In normal processing)
(Transmission to the F381A)
STX
Delimiter
0LSM 3APE11
PELSAM
Delimiter
Undefined
Work No. used for measurement
Header (If there is no header, no data will result.)
Waveform update
0: Not made
1: Made
(If an update is made, this bit changes
from 0 to 1 only once upon reading.)
518
Equipment ID
* Equipment ID is a parameter.
(It can be set from the touch panel only
when the SD card slot option/Ethernet option
is mounted.)
STX
Delimiter
N1G
F381A’s return
(In abnormal condition)
Header (If there is no header, no data will result.)
NG No.
1: Receipt of a statement different from the command format

Table of Contents

Related product manuals