83
5 COMMUNICATIONS
83
COMMUNICATIONS
Chapter
5
Communication method (when the Communication Mode is Normal)
By transmitting commands from the host, operations corresponding to the commands are executed.
-List of items that can be communicated
Item group
Set value, operation,
display item
Read Write Cal. Reference
Main Load (display)
〇××
Display read command
DPM (display)
〇××
Display read command
Work No. (display)
〇××
Display read command
Measurement status
display
○××
Display read command
Waveform update check
〇××
Waveform update check/
equipment ID read
command
Measurement waveform
〇××
Waveform read command
Equipment ID
〇××
Waveform update check/
equipment ID read
command
Result Result (display)
〇××
Hold result read
command
Result
〇××
Result read command
Wave No.
〇〇×
Wave No. read/wave No.
write command
First Setting Y-axis Setting Exc. Voltage
〇〇×
Set value read/
set value write command
Unit
〇〇×
Set value read/
set value write command
Decimal Place
〇〇×
Set value read/
set value write command
Zero Cal.
〇×〇
Set value read/
Zero cal. command
Equiv. Cal.
(rated output)
〇〇×
Set value read/
set value write command
Equiv. Cal.
(rated capacity)
〇〇×
Set value read/
set value write command
Actual Cal.
××〇
Actual cal. command
Overload
〇〇×
Set value read/
set value write command
Increment
〇〇×
Set value read/
set value write command
Analog Filter
〇〇×
Set value read/
set value write command
Digital Filter
〇〇×
Set value read/
set value write command
DZ Limit
〇〇×
Set value read/
set value write command

Table of Contents