EasyManua.ls Logo

Unipulse F381A - Waveform Write Command

Unipulse F381A
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
97
5 COMMUNICATIONS
97
COMMUNICATIONS
Chapter
5
- Waveform write command
Example: Writing to Comparison Waveform (LO limit) of Work No. 3
Writing “3” to Work No.
0
STX
0WVA0SP0
F381A’s return
(In normal processing)
Waveform data
40002-7
-100.00
1E0
Delimiter
4
2nd Waveform data
Checksum of the waveform data
All the read waveform data is totaled by ignoring respective decimal points,
and the two low-order bytes of the result are expressed in 4-digit hexadecimal.
Example) Checksum of three waveform data
-01.00 + (+31.25) + (+12.99)
-0100 + (+3125) + (+1299) 4324 10E4H
Waveform data
Amount of data: Data for the specified range “the end of the range – the start of the range + 1”
2048 data in the example (2048 × 7 bytes)
* If the same data No. is specified for the start and the end of the range,
only one data is read.
0: Load: -09999 to +09999 (with a decimal point)
1: Displacement (Front): 0 to 10235 (with a decimal point)
Displacement (Back): -10235 to 0 (with a decimal point)
Time: +00000 to +51175 (with a decimal point)
The unit of time differs according to Measurement Length, X-axis Setting.
0.5s: Unit ms
1.0s: Unit ms
2.0s: Unit ms
5.0s: Unit ms
10.00s: Unit s
Command received by the F381A
+120.99
STX
Delimiter
N1G
F381A’s return
(In abnormal condition)
Header (If there is no header, no data will result.)
NG No.
1: Receipt of a statement different from the command format
2: Attempt to write a set value outside the setting range
-090.87
SMU
at the start of the range at the end of the range
Host
(Transmission to the F381A)
Item No. (See the list of set value commands.)
Work No. in the example
Item group (See the list of set value commands.)
Work Setting in the example
00+0000003W1 0
Delimiter
Data to write
“3” in the example

Table of Contents

Related product manuals