EasyManua.ls Logo

Unipulse F381A - 5 COMMUNICATIONS; 5-1. RS-232 C Communication

Unipulse F381A
164 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
81
5 COMMUNICATIONS
81
COMMUNICATIONS
Chapter
5
5-1. RS-232C
■Outline
- Results can be read.
- Hold results can be read.
- Measurement waveforms can be read.
- Comparison waveforms can be read and written.
- Set values can be read and written.
- Wave Nos. can be read and written.
- Hold results can be automatically output upon completion of measurement.
- The communication check function is included.
(See "■Communication establishment procedure"on page 23 (2-4.RS-232C Connection))
■RS-232C setting
Make RS-232C communication settings by Communication Setting.
Operation
Main screen→Setting→First Setting→Com. Setting
- Transmission Speed
Setting range
Operation
(1200, 2400, 4800, 9600, 19.2k, 38.4k bps)
Main screen→Setting→First Setting→Com. Setting→Speed
- Data Bit
Operation
Setting range (7, 8 bit)
Main screen→Setting→First Setting→Com. Setting→Data Bit
5 COMMUNICATIONS