t2: Delay time between the instant when the Start input is turned OFF and the instant when the
measurable section is started ... 1.5ms
(However, it varies depending on the Measurement Start Condition.)
t3: Delay time between the instant when the measurement is stopped (the Stop input is turned ON)
and the instant when the Result output is turned ON ... Approx. 50ms
(However, there are differences between measurements.)
t4: Delay time between the instant when the Result output is turned ON and the instant when the
Complete output is turned ON ... Approx. 30ms
* Be sure to check that the output is OFF, and then turn OFF the Start input.
How to check wiring
Operation
Main screenSettingFirst SettingSystem SettingSelf-CheckEXT Check
Output
Press the output signal key, and check that there is input to the connected equipment.
(Pressing the key turns ON the output.)
Input
Turn ON the output of the connected equipment.
The pin recognized by the F381A turns yellow.