32
3 SCREENS AND OPERATIONS
32
SCREENS AND OPERATIONS
Chapter
3
Comprehensive judgmentDisplays the judgments (Y-axis and X-axis) of each section and
the judgments of waveform comparisons overall.
The order of priority is as follows:
H/L > H,L > NG > OK
Work No. Displays the work No. used for measurement.
SECT.15Displays the Y-axis (load) and X-axis (displacement or time) values of the
judgment point of each section and judgment results.
Wave Displays the Y-axis (load) and X-axis (displacement or time) values of the point
at which the upper/lower limit comparison waveform is first exceeded, and the
Y-axis (load) judgment result.
No. Displays the order of measurement. No. 01 is the most recent result.
Wave No. Displays the Wave No. associated with judgment results. It is not displayed if
not established.
Keys
Deletes all comparison results.
When the Delete key is pressed, the deletion
  confirmation screen appears.
(display No. selection keys)Switch the number displayed.
Switches the display to List.
Moves to the Main screen.
For the 41st and subsequent measurements, the data of No. 40 is deleted, and
the most recent data is saved at No. 01.
Measurement can be made as the comparison result screen is displayed.
However, measurement results are updated.
For checking the comparison
results of the same contents, stop measurement.